7.2.21. Floors, walls and ceilings: The rooms of a dismembering plant must comply with the following conditions:
(a)  floors must be shock-resistant, impermeable, washable and non-slippery. They must have a slope of 2 cm/m towards drains and have drainage pipes with a diameter of at least 10 cm and equipped with a grid opening of at least 9 dm2 for the drainage of washing water;
(b)  walls must be faced with impermeable, smooth and rot-proof material;
(c)  walls other than those of the sector mentioned in subparagraph iii of subparagraph a of the first paragraph of section 7.2.6 or those of the refrigeration or freezing room of the dismembering plants operated under an “animal food cannery”, “general preparation” or “special preparation” category permit, shall be faced with shock-resistant materials;
(d)  subparagraphs b and c apply to lavatory walls up to a height of 130 cm from the floor level.
This section does not apply to a dismembering plant referred to in section 7.2.11.1.
R.R.Q., 1981, c. P-29, r. 1, s. 7.2.21; O.C. 1122-2004, s. 10.